smpp-ota-tool

The smpp-ota-tool allows users to send OTA SMS messages containing APDU scripts (RFM, RAM) via an SMPP server. The intended audience are developers who want to test/evaluate the OTA SMS interface of a SIM/UICC/eUICC. smpp-ota-tool is intended to be used as a companion tool for pySim-smpp2sim, however it should be usable on any other SMPP server (such as a production SMSC of a live cellular network) as well.

From the technical perspective smpp-ota-tool takes the role of an SMPP ESME. It takes care of the encoding, encryption and checksumming (signing) of the RFM/RAM OTA SMS and eventually submits it to the SMPP server. The program then waits for a response. The response is automatically parsed and printed on stdout. This makes the program also suitable to be called from shell scripts.

Note

In the following we will we will refer to SIM as one of the following: SIM, USIM, ISIM, UICC, eUICC, eSIM.

Applying OTA keys

Depending on the SIM type you will receive one or more sets of keys which you can use to communicate with the SIM through a secure channel protocol. When using the OTA SMS method, the SCP80 protocol is used and it therefore crucial to use a keyset that is actually suitable for SCP80.

A keyset usually consists of three keys:

  1. KIC: the key used for ciphering (encryption/decryption)

  2. KID: the key used to compute a cryptographic checksum (signing)

  3. KIK: the key used to encrypt/decrypt key material (key rotation, adding of new keys)

From the transport security perspective, only KIC and KID are relevant. The KIK (also referenced as “Data Encryption Key”, DEK) is only used when keys are rotated or new keys are added (see also ETSI TS 102 226, section 8.2.1.5).

When the keyset is programmed into the security domain of the SIM, it is tied to a specific cryptographic algorithm (3DES, AES128 or AES256) and a so called Key Version Number (KVN). The term “Key Version Number” is misleading, since it is actually not a version number. It is a unique identifier of a certain keyset which also identifies for which secure channel protocol the keyset may be used. Keysets with a KVN from 1-15 (0x01-0x0F) are suitable for SCP80. This means that it is not only important to know just the KIC/KID/KIK keys. Also the related algorithms and the KVN numbers must be known.

Note

SCP80 keysets typically start counting from 1 upwards. Typical configurations use a set of 3 keysets with KVN numbers 1-3.

Addressing an Application

When communicating with a specific application on a SIM via SCP80, it is important to address that application with the correct parameters. The following two parameters must be known in advance:

  1. TAR: The Toolkit Application Reference (TAR) number is a three byte value that uniquely addresses an application on the SIM. The exact values may vary (see also ETSI TS 101 220, Table D.1).

  2. MSL: The Minimum Security Level (MSL) is a bit-field that dictates which of the security measures encoded in the SPI are mandatory (see also ETSI TS 102 225, section 5.1.1).

A practical example

Note

This tutorial assumes that pySim-smpp2sim is running on the local machine with its default parameters. See also pySim-smpp2sim.

Let’s assume that an OTA SMS shall be sent to the SIM RFM application of an sysmoISIM-SJA2. What we want to do is to select DF.GSM and to get the select response back.

We have received the following key material from the SIM vendor:

KIC1: F09C43EE1A0391665CC9F05AF4E0BD10
KID1: 01981F4A20999F62AF99988007BAF6CA
KIK1: 8F8AEE5CDCC5D361368BC45673D99195
KIC2: 01022916E945B656FDE03F806A105FA2
KID2: D326CB69F160333CC5BD1495D448EFD6
KIK2: 08037E0590DFE049D4975FFB8652F625
KIC3: 2B22824D0D27A3A1CEEC512B312082B4
KID3: F1697766925A11F4458295590137B672
KIK3: C7EE69B2C5A1C8E160DD36A38EB517B3

Those are three keysets. The enumeration is directly equal to the KVN used. All three keysets are 3DES keys, which means triple_des_cbc2 is the correct algorithm to use.

Note

The key set configuration can be confirmed by retrieving the key configuration using get_data key_information from within an SCP02 session on ADF.ISD.

In this example we intend to address the SIM RFM application on the SIM. Which according to the manual has TAR B00010 and MSL 0x06. When we hold 0x06 = 0b00000110 against the SPI coding chart (see also ETSI TS 102 225, section 5.1.1). We can deduct that Ciphering and Cryptographic Checksum are mandatory.

Note

The MSL (see also ETSI TS 102 226, section 6.1) is assigned to an application by the SIM issuer. It is a custom decision and may vary with different SIM types/profiles. In the case of sysmoISIM-SJS1/SJA2/SJA5 the counter requirement has been waived to simplify lab/research type use. In productive environments, SIM applications should ideally use an MSL that makes the counter mandatory.

In order to select DF.GSM (0x7F20) and to retrieve the select response, two APDUs are needed. The first APDU is the select command A0A40000027F20 and the second is the related get-response command A0C0000016. Those APDUs will be concatenated and are sent in a single message. The message containing the concatenated APDUs works as a script that is received by the SIM RFM application and then executed. This method poses some limitations that have to be taken into account when making requests like this (see also ETSI TS 102 226, section 5).

With this information we may now construct a commandline for smpp-ota-tool.py. We will pass the KVN as kid_idx and kic_idx (see also ETSI TS 102 225, Table 2, fields KIc and KID). Both index values should refer to the same keyset/KVN as keysets should not be mixed. (smpp-ota-tool still provides separate parameters anyway to allow testing with invalid keyset combinations)

$ PYTHONPATH=./ ./contrib/smpp-ota-tool.py --kic F09C43EE1A0391665CC9F05AF4E0BD10 --kid 01981F4A20999F62AF99988107BAF6CA --kid_idx 1 --kic_idx 1 --algo-crypt triple_des_cbc2 --algo-auth triple_des_cbc2 --tar B00010 --apdu A0A40000027F20 --apdu A0C0000016
2026-02-26 17:13:56 INFO Connecting to localhost:2775...
2026-02-26 17:13:56 INFO C-APDU sending: a0a40000027f20a0c0000016...
2026-02-26 17:13:56 INFO SMS-TPDU sending: 02700000281506191515b00010da1d6cbbd0d11ce4330d844c7408340943e843f67a6d7b0674730881605fd62d...
2026-02-26 17:13:56 INFO SMS-TPDU sent, waiting for response...
2026-02-26 17:13:56 INFO SMS-TPDU received: 027100002c12b000107ddf58d1780f771638b3975759f4296cf5c31efc87a16a1b61921426baa16da1b5ba1a9951d59a39
2026-02-26 17:13:56 INFO SMS-TPDU decoded: (Container(rpl=44, rhl=18, tar=b'\xb0\x00\x10', cntr=b'\x00\x00\x00\x00\x00', pcntr=0, response_status=uEnumIntegerString.new(0, 'por_ok'), cc_rc=b'\x8f\xea\xf5.\xf4\x0e\xc2\x14', secured_data=b'\x02\x90\x00\x00\x00\xff\xff\x7f \x02\x00\x00\x00\x00\x00\t\xb1\x065\x04\x00\x83\x8a\x83\x8a'), Container(number_of_commands=2, last_status_word=u'9000', last_response_data=u'0000ffff7f2002000000000009b106350400838a838a'))
2026-02-26 17:13:56 INFO R-APDU received: 0000ffff7f2002000000000009b106350400838a838a 9000
0000ffff7f2002000000000009b106350400838a838a 9000
2026-02-26 17:13:56 INFO Disconnecting...

The result we see is the select response of DF.GSM and a status word indicating that the last command has been processed normally.

As we can see, this mechanism now allows us to perform small administrative tasks remotely. We can read the contents of files remotely or make changes to files. Depending on the changes we make, there may be security issues arising from replay attacks. With the commandline above, the communication is encrypted and protected by a cryptographic checksum, so an adversary can neither read, nor alter the message. However, an adversary could still replay an intercepted message and the SIM would happily execute the contained APDUs again.

To prevent this, we may include a replay protection counter within the message. In this case, the MSL indicates that a replay protection counter is not required. However, to extended the security of our messages, we may chose to use a counter anyway. In the following example, we will encode a counter value of 100. We will instruct the SIM to make sure that the value we send is higher than the counter value that is currently stored in the SIM.

To add a replay connection counter we add the commandline arguments –cntr-req to set the counter requirement and –cntr to pass the counter value.

$ PYTHONPATH=./ ./contrib/smpp-ota-tool.py --kic F09C43EE1A0391665CC9F05AF4E0BD10 --kid 01981F4A20999F62AF99988107BAF6CA --kid_idx 1 --kic_idx 1 --algo-crypt triple_des_cbc2 --algo-auth triple_des_cbc2 --tar B00010 --apdu A0A40000027F20 --apdu A0C0000016 --cntr-req counter_must_be_higher --cntr 100
2026-02-26 17:16:39 INFO Connecting to localhost:2775...
2026-02-26 17:16:39 INFO C-APDU sending: a0a40000027f20a0c0000016...
2026-02-26 17:16:39 INFO SMS-TPDU sending: 02700000281516191515b000103a4f599e94f2b5dcfbbda984761b7977df6514c57a580fb4844787c436d2eade...
2026-02-26 17:16:39 INFO SMS-TPDU sent, waiting for response...
2026-02-26 17:16:39 INFO SMS-TPDU received: 027100002c12b0001049fb0315f6c6401b553867f412cefaf9355b38271178edb342a3bc9cc7e670cdc1f45eea6ffcbb39
2026-02-26 17:16:39 INFO SMS-TPDU decoded: (Container(rpl=44, rhl=18, tar=b'\xb0\x00\x10', cntr=b'\x00\x00\x00\x00d', pcntr=0, response_status=uEnumIntegerString.new(0, 'por_ok'), cc_rc=b'\xa9/\xc7\xc9\x00"\xab5', secured_data=b'\x02\x90\x00\x00\x00\xff\xff\x7f \x02\x00\x00\x00\x00\x00\t\xb1\x065\x04\x00\x83\x8a\x83\x8a'), Container(number_of_commands=2, last_status_word=u'9000', last_response_data=u'0000ffff7f2002000000000009b106350400838a838a'))
2026-02-26 17:16:39 INFO R-APDU received: 0000ffff7f2002000000000009b106350400838a838a 9000
0000ffff7f2002000000000009b106350400838a838a 9000
2026-02-26 17:16:39 INFO Disconnecting...

The SIM has accepted the message. The message got processed and the SIM has set its internal to 100. As an experiment, we may try to re-use the counter value:

$ PYTHONPATH=./ ./contrib/smpp-ota-tool.py --kic F09C43EE1A0391665CC9F05AF4E0BD10 --kid 01981F4A20999F62AF99988107BAF6CA --kid_idx 1 --kic_idx 1 --algo-crypt triple_des_cbc2 --algo-auth triple_des_cbc2 --tar B00010 --apdu A0A40000027F20 --apdu A0C0000016 --cntr-req counter_must_be_higher --cntr 100
2026-02-26 17:16:43 INFO Connecting to localhost:2775...
2026-02-26 17:16:43 INFO C-APDU sending: a0a40000027f20a0c0000016...
2026-02-26 17:16:43 INFO SMS-TPDU sending: 02700000281516191515b000103a4f599e94f2b5dcfbbda984761b7977df6514c57a580fb4844787c436d2eade...
2026-02-26 17:16:43 INFO SMS-TPDU sent, waiting for response...
2026-02-26 17:16:43 INFO SMS-TPDU received: 027100000b0ab0001000000000000006
2026-02-26 17:16:43 INFO SMS-TPDU decoded: (Container(rpl=11, rhl=10, tar=b'\xb0\x00\x10', cntr=b'\x00\x00\x00\x00\x00', pcntr=0, response_status=uEnumIntegerString.new(6, 'undefined_security_error'), cc_rc=b'', secured_data=b''), None)
Traceback (most recent call last):
File "/home/user/work/git_master/pysim/./contrib/smpp-ota-tool.py", line 238, in <module>
 resp, sw = smpp_handler.transceive_apdu(apdu, opts.src_addr, opts.dest_addr, opts.timeout)
            ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
File "/home/user/work/git_master/pysim/./contrib/smpp-ota-tool.py", line 162, in transceive_apdu
  raise ValueError("Response does not contain any last_response_data, no R-APDU received!")
ValueError: Response does not contain any last_response_data, no R-APDU received!
2026-02-26 17:16:43 INFO Disconnecting...

As we can see, the SIM has rejected the message with an undefined_security_error. The replay-protection-counter ensures that a message can only be sent once.

Note

The replay-protection-counter is implemented as a 5 byte integer value (see also ETSI TS 102 225, Table 3). When the counter has reached its maximum, it will not overflow nor can it be reset.

smpp-ota-tool syntax

Tool to send OTA SMS RFM/RAM messages via SMPP

usage: contrib/smpp-ota-tool.py [-h] [--host HOST] [--port PORT]
                                [--system-id SYSTEM_ID] [--password PASSWORD]
                                [--verbose]
                                [--algo-crypt {single_des,triple_des_cbc2,aes_cbc}]
                                [--algo-auth {single_des,triple_des_cbc2,aes_cmac}]
                                --kic KIC [--kic-idx KIC_IDX] --kid KID
                                [--kid-idx KID_IDX] [--cntr CNTR] --tar TAR
                                [--cntr-req {no_counter,counter_no_replay_or_seq,counter_must_be_higher,counter_must_be_lower}]
                                [--no-ciphering]
                                [--rc-cc-ds {no_rc_cc_ds,rc,cc,ds}]
                                [--por-in-submit] [--por-no-ciphering]
                                [--por-rc-cc-ds {no_rc_cc_ds,rc,cc,ds}]
                                [--por-req {no_por,por_required,por_only_when_error}]
                                [--src-addr SRC_ADDR] [--dest-addr DEST_ADDR]
                                [--timeout TIMEOUT] -a APDU

Named Arguments

--host

Host/IP of the SMPP server

Default: “localhost”

--port

TCP port of the SMPP server

Default: 2775

--system-id

System ID to use to bind to the SMPP server

Default: “test”

--password

Password to use to bind to the SMPP server

Default: “test”

--verbose

Enable verbose logging

Default: False

--algo-crypt

Possible choices: single_des, triple_des_cbc2, aes_cbc

OTA crypt algorithm

Default: “triple_des_cbc2”

--algo-auth

Possible choices: single_des, triple_des_cbc2, aes_cmac

OTA auth algorithm

Default: “triple_des_cbc2”

--kic

OTA key (KIC)

--kic-idx

OTA key index (KIC)

Default: 1

--kid

OTA key (KID)

--kid-idx

OTA key index (KID)

Default: 1

--cntr

replay protection counter

Default: 0

--tar

Toolkit Application Reference

--cntr-req

Possible choices: no_counter, counter_no_replay_or_seq, counter_must_be_higher, counter_must_be_lower

Counter requirement

Default: “no_counter”

--no-ciphering

Disable ciphering

Default: False

--rc-cc-ds

Possible choices: no_rc_cc_ds, rc, cc, ds

message check (rc=redundency check, cc=crypt. checksum, ds=digital signature)

Default: “cc”

--por-in-submit

require PoR to be sent via SMS-SUBMIT

Default: False

--por-no-ciphering

Disable ciphering (PoR)

Default: False

--por-rc-cc-ds

Possible choices: no_rc_cc_ds, rc, cc, ds

PoR check (rc=redundency check, cc=crypt. checksum, ds=digital signature)

Default: “cc”

--por-req

Possible choices: no_por, por_required, por_only_when_error

Proof of Receipt requirements

Default: “por_required”

--src-addr

SMS source address (MSISDN)

Default: “12”

--dest-addr

SMS destination address (MSISDN)

Default: “23”

--timeout

Maximum response waiting time

Default: 10

-a, --apdu